Nabertherm error codes and warnings, explained

Your kiln has stopped and the controller is showing a number. This page says what each one means on a Series 500 controller — B500, B510, C540, C550, P570 and P580 — and what to check first.

Written from Nabertherm’s own operating manual, document M03.0022. For the full remedy steps, the wiring and anything involving the switchgear, go to the manual itself: M03.0022 (English, PDF). It is the authority; this is an index you can search.

How the numbering works

An error is an ID and a sub-ID — 04-01 is family 04, item 01. The family tells you roughly where to look before you read anything else:

Warnings are numbered separately, 00 to 18, and are a different thing: they generally do not stop a firing. They also do not go into the controller’s error archive, so a warning you did not see on the screen at the time is a warning you will not find later.

Some errors can only be cleared by switching the controller off and on — acknowledging them on the screen is not enough. The manual marks those; they are mostly in family 03.

Errors

01 — Communication

CodeWhat it meansCheck first
01-01Bus zone. The control unit has lost its link to a control module. Is the module seated firmly? Is its LED red? Then the cable between unit and module, and the plug at the control unit.
01-02Bus communications module. The link to the Ethernet/USB module is down. The same two things: the module seated firmly, and the cable to it. This is also the module the cloud reports through, so this one can be why the kiln has gone quiet online.

02 — Sensors

CodeWhat it meansCheck first
02-01Thermocouple open — a broken circuit where the temperature should be. The thermocouple, its terminals and its cable; the contacts in plug X1 on the control module.
02-02Thermocouple connection. The thermocouple type set in the controller, and the polarity — a reversed pair reads as this.
02-03Cold junction (“compare point”) error.Control module fault.
02-04Cold junction too hot — around 70 °C in the switchgear. Why the cabinet is that hot: ventilation, ambient, a failing fan.
02-05Cold junction too cold — around −10 °C. An unheated workshop in winter is the usual answer.
02-06Encoder separated — under 2 mA on the 4–20 mA input. The sensor and its cable.
02-07PT100 or PT1000 sensor defective.The sensor, and its cable for a break or a short.

03 — The controller itself

CodeWhat it meansCheck first
03-01System memory. Often after a firmware update.Off and on. If it persists, the control unit.
03-02ADC error — the analogue-to-digital converter is not talking to the controller.Control module replacement.
03-03File system defective — display and memory chip not communicating.Control unit replacement.
03-04System monitoring — the watchdog caught the control unit. A USB drive pulled out too early can do this. Off and on first.
03-05Zone system monitoring — the watchdog on a control module.Off and on; then the module.
03-06Self-test error.Nabertherm service.
03-07Analog output at the wrong voltage. An electrician’s job: de-energise, disconnect the loads, retry. If it clears, the load; if not, the module.

04 — Monitoring

This is the family a potter actually meets. These are not electronics faults — they are the controller saying the kiln is not doing what it was told.

CodeWhat it meansCheck first
04-01No heater power. Twelve minutes of a ramp with the elements called for and no temperature rise. Elements and their connections; the safety contactor; the door switch; the heating control. This is the one that usually means an element has gone.
04-02Excess temperature. A control zone is 50 K over the maximum setpoint (above 200 °C). It can also mean a programme was started with the kiln already hotter than the programme’s own maximum. The solid-state relay, the thermocouple, the controller — a stuck relay keeps heating. If you started hot, let it cool and start again.
04-03Power failure beyond the restart limit, or the main switch thrown mid-programme. Stop the programme before the main switch. If the supply is the problem, a UPS.
04-04A configured alarm fired.Whichever alarm you set.
04-05Auto-tune failed — the values came out implausible. Do not auto-tune at the bottom of the kiln’s range.
Battery weakThe clock is wrong and a power failure may not be handled properly. Export your parameters to USB first, then replace the battery.

05 — Self-tests and the rest

CodeWhat it meansCheck first
05-00General malfunction in the control or Ethernet module. Nabertherm service, with the service export.
05-01Self-test failed, lower limit switch.Off and on to repeat the self-test; if it fails again, Nabertherm service.
05-02Self-test failed, upper limit switch.
05-03Self-test failed, heating.
05-04Vacuum pump / pressure switch — evacuation did not succeed. Is the pump on? The connection to it, the table seal, and dirt on the seal.

Warnings

These do not normally stop a firing, and they are not written to the error archive — they appear on the display and in a parameter export, and nowhere else.

No.What it meansCheck first
00Gradient monitoring tripped.Usually the gradient is set too tight for the kiln.
01No control parameters — no P value in the PID set.Enter a P value; it cannot be 0.
02Charge thermocouple missing or defective, with charge control on.Plug one in, or turn charge control off in the programme.
03Cooling thermocouple missing or defective.Controlled cooling falls back to the control zone thermocouple.
04Documentation thermocouple missing or defective.The thermocouple and its cable.
05A power failure happened, but the programme was not interrupted.Nothing to do.
06–11Alarm 1 and Alarm 2, band / min / max.Either the control parameters want tuning or the alarm is set too narrow.
12–15External alarms on inputs 1 and 2.Whatever is wired to that input.
16No USB drive inserted.Insert one to export.
17USB import or export failed.FAT32, full format not quick, up to 2 TB. Never edit the XML in a text editor. Imports must be in the Import folder.
18Heating blocked — a door switch is fitted and the door is open.Close the door.

Where this dashboard shows it

Kiln Dashboard reads the controller’s error code through Nabertherm’s cloud and shows it on the Live view, and carries it into the firing’s spreadsheet export so a run that failed has the code attached to it afterwards.

One honest limit, and what to do about it. The dashboard shows the code the cloud reports, as a number. No kiln on this install has ever reported a non-zero one, so I have not been able to confirm how that number lines up with the ID–sub-ID pairs above, and I would rather say so than publish a mapping I have not seen.

So take the pair off the controller’s own screen, which is the authority on which error you have, and read it here. If the two disagree, or the code is not in the tables above, tell me what each one says and I will fix this page.

When the answer is Nabertherm

Plenty of these end at a module, a control unit or a self-test that will not pass, and the honest answer is that the manufacturer should look at it. Nothing on this page replaces either of these, and both are worth having open before you take anything apart:

Anything involving the switchgear is an electrician’s job, not a potter’s: the manual says so and so does this page. De-energise the furnace first, and let the chamber cool.